Measured on the customer's own sensors. Read against the Systel Audit Archive.
Every figure below is from a plant on the programme, read from its dashboard against its measured baseline. Names and logos appear only with the customer's written approval.
A 3-unit spinning group in Tamil Nadu: specific power 0.189 → 0.162 kW/CFM in nine months — with no new compressor.
"Our compressed-air bill went up every year and every supplier told us to buy a bigger compressor. We had no way to check."
- Non-productive air 31% of capacity, concentrated in the autoconer section
- Header at 7.4 bar against a 6.6 bar requirement at the farthest machine
- Dryer 2 at +9 °C pressure dew point, afternoons only
- One 75 kW compressor unloaded 6–8 hours a day
- Resequenced the compressors — a two-hour job
- Two splicer-and-leak campaigns with its own fitters, verified on night-time flow
- Header set-point stepped down 0.2 bar a week to 6.8 bar
- Shaded the dryer intake; dew-point alarm set at +3 °C
"Every supplier told us to buy a bigger compressor. Systel looked at the dashboard for ten minutes and told us to change the splicers. They were right."
The compressors said 0.16 kW/CFM. The sensors said 0.196.
A 100,000-spindle mill in Tamil Nadu ran two screw compressors, 850 and 450 CFM, 132 and 75 kW, at a paper specific energy of 0.16 kW/CFM. The plant wanted to get from about 1,300 CFM to 600 and did not know where to begin.
The monitoring system showed the pair delivering 1,120 CFM for about 220 kW: 0.196 kW/CFM, 18% worse than claimed. Spinning and autoconer were drawing 800 CFM against a need of about 300; preparatory 320 against 50. The archive had seen both patterns before: artificial demand from over-set machine pressures, and leaks that returned after every survey.
- Reset machine operating pressures in spinning, autoconer and preparatory — about 150 CFM of artificial demand removed
- Fixed leaks department by department, watching each department's daily consumption instead of waiting for the next survey — about 350 CFM
- Adjusted compressor inlet, ambient and set-point conditions and carried out the maintenance the readings pointed to
- Avoided the large spares earlier leak-survey agencies had recommended — spares spend down by about 60%
"14% reduction in compressor energy consumption. 10,368 kWh saved per day after installing Systel's smart online compressed-air monitoring system."
What would your plant measure?
A feasibility visit gives a tentative projection. The baseline gives the real number.